Color Kinetics Data Enabler Pro Power Relay - Version 2.0.0#
Module Summary#
Control the Power relay within a PCK Data Enabler Pro.
Module Status#
This IO Module is stable and has been tested internally.
If you encounter any issues with this module, or have any feedback regarding its operation, please contact our support team.
Release Notes#
Version 2.0#
Added status variables.
Improved logging.
Added Log Actions and Extended Logging options.
Updated documentation.
Minor point releases (eg. 1.1.x) will be for small fixes and may not be listed here.
Operation#
Instance Properties#
One instance is required for each Data Enabler Pro to be controller, defined by its IP Address.
The Retries property is number of times to send a status query to check that the setting has been correctly applied.
Checking Log Actions will provide log messages when module Actions are called and whether the action was verified successful.
Checking Extended Logging will provide more detailed logs on communication between the Controller and the Data Enabler. This is intended for diagnostics and problem solving and should ideally be disabled during normal operation.
Status Variables#
The IO Modules tab of the web interface provides status variables to shows information about the module and monitor its state.
IP Address | The IP address of the Data Enabler Pro set in the instance properties. |
Last Action | The last Action called. |
Last Command Sent | The last command sent to the Data Enabler pro. This may be different from the last action for example in the case of sending a query following a request to change state. |
Last Status | A description of how the success of the request based on the response received. |
Actions#
Set Power#
Sends a command to the Data Enabler Pro to set its power setting to the Action specified.
Turn Off After No Data#
Sends a command to the Data Enabler Pro to turn off the power relay when no data has been received after the Timeout period.
Turn Off After Black Data#
Sends a command to the Data Enabler Pro to turn off the power relay when all channels are set to 0, after the Timeout period.